ANALOG - DIGITAL TRAINER
ANALOG - DIGITAL TRAINER
 

Specifications

  • Aesthetically designed injection moulded electronic desk / Master unit carrying useful experiment resources like variable.
  • Power supplies / Status Switches / Indicator probe / Pulsar / Function Generator DPMs etc.
  • Connection through study 4mm Banana Sockets & patch cords.
  • Built in bread board panel with 1280 tie points and 400 distribution points totalling to 1680 points along with 4mm banana sockets for tapping from the trainer +5V, +/-12V/ GND for the circuits to be assembled on bread board using single stand (#22/24) wire.
View Detail.
   
AM FM RADIO KIT
AM FM RADIO KIT
 

Salient Features

  • Transistorised superhet AM & FM radio either in assembled OR CKD form.
  • Useful for hobbyist, ITI, Polytechnic Engg. students.
  • Battery low indication LED
  • Onboard earphone jack & speaker.
  • Detailed ident of components enables user to understand complete assembly as well as working.
  • Single PCB construction.
  • Illustrative user's guide with assembly instruction.

Specifications
>>AM & FM Radio in CKD form
a) Unassembled PCB
b) Components

Typical Components
 
Trans-istors Coils Capa-citors Resistors Diodes Speaker Earphone Socket Test points
Qty. 8 13 45 47 5 1 1 17

OR AM & FM Radio - Fully assembled tested radio kit.

  • Clearly identified functional blocks viz. Mixer, Oscillator, Amplifier, Detector & Audio Amplifier with volume control.
  • Test points at each stage of both AM & FM sections - Total 17 nos
  • AM radio specifications
    Tuning range 520kHz to 1620kHz. IF Frequency 455kHz.
  • FM radio specifications
    Tuning range 88MHz to 108MHz.
    IF Frequency 10.7MHz.
  • Power supply : 9V either using onboard battery or external DC power supply with ON/OFF switch.
  • Mechanical Dimensions : 282mm X 127mm, packed in a compact corrugated box with detacheable baffel.
View Detail.
   
Advance Power Electronics Trainer
Advance Power Electronics Trainer
 

Salient Features

  • Each of following advance PE trainer may need a few set of associated panels (4 nos. typically) which are mounted in a light weight sturdy aluminum flat demo panel system.
  • Facilitates easy and safe wiring by students due to 4mm sturdy shrouded banana patch cords and shrouded socket arrangement for high voltage circuits.
  • Each panel has ABS molded plastic sturdy enclosure, and colorful screw less overlays showing circuit diagram & its connection tag numbers for easy understanding and connections.
  • Set of Instructor Guide & Student Workbook.

Mechanical specifications:
1. Auminum rack: of 1* 4 matrix used as flat panel demo panel system to house 4 panels needed for the trainer ordered.
2. Dimensions :500(H)*910(L)*300(D)mm

View Detail.
   
Air Blower
Air Blower
 
Electric air blower with adjustable speed control. Suitable for use with Linear Air Track Kit. Supplied complete with air hose. Input 230V A.C.
View Detail.
   
Archimede Principle Apparatus
Archimede Principle Apparatus
 
Bucket and cylinder for demonstrating that a body submerged in water loses weight equal to its own volume of water. Made of nickel plated brass.
View Detail.
   
Aquarium
Aquarium
 

Glass panels are sealed by silicon rubber into strong aluminium channels. Suitable for fresh or salt water.

450 x 250 x 250 mm.

600 x 250 x 250 mm.

View Detail.
   
Aquatic Net
Aquatic Net
 

Strongly built for sweeping up of aquatic fauna and as ageneral utility aquatic net.Net ring and handle can be separated for ease of carriage.Strong ‘D’ shaped ring frame of 30 cm dia., with stout handle.

View Detail.
   
Animal Cage
Animal Cage
 

For small animals, framework covered with metal mesh. Provided with water bottle and feeding tray. An extra tray is provided below the cage for collection of animal excreta.Feeding arrangement allows removal of bin from outside of cage with automatic drop closure.

30x23x30 cm

45x45x38 cm

View Detail.
   
Accessories Set, Van De Graaff
Accessories Set, Van De Graaff
 
The set comprises of :
  • Faraday Pail
  • Perspex cylinder with suspended metallised sphere
  • Head of hair
  • Point discharge
  • Electric whirl
  • Neon Bulb
  • Electric Tester
View Detail.
   
Ammeter
Ammeter
 

Ammeter D.C.
Moving coil meters. Scale length 60mm approx. with knife edge pointer and anti parallax mirror scale. Size 80x110x80mm. Accuracy ±2% F.S.D.

Single Range
01 Microammeter, 025μA
02 Microammeter, 050μA
03 Microammeter, 0100μA
04 Microammeter, 0500μA
05 Milliammeter, 01mA
06 Milliammeter, 010mA
07 Milliammeter, 0100mA
08 Milliammeter, 0500mA
09 Ammeter, 01A
10 Ammeter, 03A
11 Ammeter, 05A
12 Ammeter, 010A
Double Range
13 Ammeter, 01A and 05A
Triple Range
14 Ammeter, 050mA, 0500mA and 05A
Rectifier type.
15 Milliammeter, 01mA
16 Milliammeter, 010mA
17 Milliammeter, 0100mA
18 Milliammeter, 0500mA
19 Ammeter, 01A
20 Ammeter, 03A
21 Ammeter, 05A
22 Ammeter, 010A
View Detail.
   
Aeration Pump With Diffuser
Aeration Pump With Diffuser
 

Accessories for Aquarium

View Detail.
   
Automatic Knife Sharpener
Automatic Knife Sharpener
 

Portable, precision automatic knife sharpener with timer 0-60 minutes to adjust sharpening time. This equipment can sharpen all microtome knives up to 140 mm in length. Complete with one universal holder, two honing plates, one bottle honing glass compound, one knife inspection block and one re-dressing pad but without micro abrasives.

View Detail.
   
Air Condensers
Air Condensers
 
Cat.No Scoket Cone Effective Length (mm)
181.01 14/23 14/23 200
181.02 19/26 19/26 200
181.03 24/29 24/29 250
181.04 19/26 19/26 400
181.05 24/29 24/29 500
181.06 34/35 34/35 500
181.07 19/26 19/26 600
181.08 24/29 24/29 750
181.09 -- 19/26 750
181.10 -- 24/29 750
181.11 -- 19/26 1000
181.12 -- 24/29 1000
View Detail.
   
Allihn Condensers (Bulb Condencer)
Allihn Condensers (Bulb Condencer)
 
Cat.No SocketConeEffective Length (mm)
190.01 --19/26200
190.02 -- 24/29 200
190.03 -- 29/32 200
190.04-- 34/35 200
190.05 -- 40/38 200
190.06 -- 50/42 200
190.07 -- 50/42 250
190.08 19/26 19/26 200
190.09 24/29 24/29 200
190.10 19/26 19/26300
190.11 24/29 24/29 300
190.12 24/29 24/29 400
190.13 24/29 24/29 500
190.14 34/35 34/35 500
View Detail.
   
Allihn Condensers (Bulb Condenser)
Allihn Condensers (Bulb Condenser)
 
Cat.No Effective Length (mm)
194.01 200
194.02 300
194.03 400
194.04 500
194.05 600
View Detail.
   
Air Condensers
Air Condensers
 
Cat.No Effective Length (mm)
196.01 400
196.02 600
196.03 750
196.04 1000
View Detail.
   
ABEL'S FLASH POINT APPARATUS.[IP 33, 170,IS-1448]
ABEL'S FLASH POINT APPARATUS.[IP 33, 170,IS-1448]
 
Used for determining of the closed cup Flash point of Petroleum Products,their mixtures,others liquids & Paints having Flash Point below 700C. The apparatus consists of one brass cup and cover fitted with shutter mechanism test flame arrangement(Oil test jet or Gas test jet) and stirrer, placed on a water bath made of copper sheet double walled. The outer jecket of the water bath is fitted with a stand. For electrically heated apparatus, heater is fitted to the stand the heat of which may be controlled different temperature regulation system of operated on 220 Volts AC mains. For Gas heated model the drum is heated by a burner. (without burner).
Optional Accessories:

IMC-475 Abel's Flash Point Apparatus temperature range-200C+700C with refrigeration system as per IP 170 with oil test jet/Gas test jet device.
IMC-552 Gas heated with oil test jet or Gas test jet without burner.
IMC-436Electric heated with oil test jet or Gas test jet without any control.
IMC-436AElectric heated with oil test jet or Gas test jet with separate energy regulator control.
IMC-436B -do -do- concealed Hot Plate.
IMC-437A Electric heated with voltage varric coper coil type.
IMC-437AA Electric heated by concealed Hot Plate with voltage varric copper coil type as per IMC-437A.
IMC-476 Same as IMC-437A. Temp. is controlled by digital temperature controller cum indicator.
View Detail.
   
Adson Forceps
Adson Forceps
 
Size 12, 15cm
View Detail.
   
Adson-Brown Forceps
Adson-Brown Forceps
 
Size 12cm
View Detail.
   
Alcohol Burner Stand
Alcohol Burner Stand
 
Ideal for use with alcohol burners. Made of nickel plated steel wire gauge. Height 125mm.
View Detail.
   
Alcohol Burner, Aluminium
Alcohol Burner, Aluminium
 
Made of die pressed aluminum. Comes with a wick and screw on cap. Height 100mm approx. Capacity 60ml.
View Detail.
   
Alcohol Burner, Glass
Alcohol Burner, Glass
 
Made of glass. Comes with a metal wick holder, wick and glass stopper. Height 100mm approx. Capacity 120ml.
View Detail.
   
Autocollimator Dual-Axis
Autocollimator Dual-Axis
 

This system is used in glass shop for checking straightness and flatness, Checking square and V blocks, checking deflection of a structure under load Measuring tapers, checking the angles of small castings. Checking the cutting angle of tools, setting angles of jigs and machine tool heads. Dark field graticules is used to get good image from un silvered glass surface or surfaces having poor reflection. Eye piece have a long eye relief, important for spectacle user. Direct reading to one minute of arc. Total measuring range of 60 minutes for measurements in both axis simultaneously. Anti- fungus coating is done on optics.

Specifications

Objective focal length300 mm
Objective clear aperture 25 mm
Barrel diameter 38 mm
Barrel length 200mm
Eye piece magnification 10x
Measuring range 25´
Read out On direct graticule at 1´
Telescope length 380mm
Illuminating bulb rating 6 v 10 watts comes with transformer.
Dimension of base Solid rugged cast iron base 75 x 250mm
Flatness of base As per ISI standard i.e. 6-7 microns within 50mm any where of the entire surface

Reflecting mirror:
Material : optical glass bsc/bk-7 front-surface coated mirror Diameter : 40 mm, rollers with c.d of 50mm.Optical square 20 x 20mm opening. Bottom and sides are optically lapped.Mirror is mounted on the base at 90° ± 2´.

View Detail.
   
Adjustable Snap Gauge
Adjustable Snap Gauge
 
Used for fast checking of mass produced jobs on the shop floor. Helps reduce inventory for different sizes in the range. Made of excellent quality shell castings. Range of 0-6 upto 337-350mm. Parallelism within 5 µm. Flatness of 1.5 µm.
View Detail.
   
Air Plug Gauge
Air Plug Gauge
 
Used for fast and precise measurement in mass & batch production. Range of 5mm to 200mm. Hard Chrome Plated. Through/Blind/Steps Bore. Two setting rings are required.
View Detail.
   
Air Ring Gauge
Air Ring Gauge
 
Range of 5 to 100mm. HCHC material. Middle/Corner Jet. Two setting rings are required.
View Detail.
   
Air Snap Gauge
Air Snap Gauge
 
Range 10mm to 150mm. Carbide resting pad. Middle/Corner jet. Two setting masters are required.
View Detail.
   
Angle Dekkor
Angle Dekkor
 
Angle Dekkor unit comes with Objective lens aperture of 28mm. Measuring range of 10 mts. Read out of 1 mtr. Telescope length of 250mm. Brass Body of 240x300mm, closed grains casting hardened, stabilities and scrapped. Light Source of 6v 15w.
View Detail.
   
Auto Temperature Scanner
Auto Temperature Scanner
 

MODEL : 6308

Range : 0-199.9, 600,1200, 1600°C

Accuracy : ± 0.5 % F.S

Mode : Auto/ Manual Selectable

Input Power : 230 V or 110 V ± 10 % 50/60 Hzt 50 Hz

Size : 96x96 mm Facia, 91x91 mm Cutout

View Detail.
   
Amp Hour Meter
Amp Hour Meter
 

MODEL : 800AH

Range : Selectable/ Programmable

Set Point : Single

Mode : Indicates present AH Value, Ampere & Total AH

Accuracy : ±0.5%

Supply : 110V AC, 220V AC or 12V DC

Signal Input : Shunt of Rectifier or Battery

Display : 6 Digit LED with Memory backup

Size : 96x96mm

View Detail.
   
AC Voltage / Current Controllers
AC Voltage / Current Controllers
 

MODEL : 8010

Range : Any Specified Voltage / Current

Set Point : Single

Accuracy : ±0.5% Supply : 110V AC, 220V AC or 12V DC

Signal Input : Direct or through CT

Display : 3½ Digit LED

Size : 96x96mm

View Detail.
   
AC Voltage / Current Controllers
AC Voltage / Current Controllers
 

MODEL : 8020

Set Point : Dual

Size : 96x96mm

View Detail.
   
Addition Strip Board
Addition Strip Board
 
This contains a board with 18 columns and 12 rows, a small tray to hold strips, 9 red strips and 9 blue strips. The red strips are marked from 1 to 9.
View Detail.
   
Addition Snake Game
Addition Snake Game
 
This is a set of 3 boxes - a red box containing 5 sets of coloured bead stairs, a black and white box containing 1 set of black and white bead stairs, and a golden box containing 23 golden ten bead bars. All 3 boxes fit on a wooden tray that comes with the set.
View Detail.
   
Area Apparatus
Area Apparatus
 
View Detail.
   
ASPIRATOR BOTTLES
ASPIRATOR BOTTLES
 

Aspirator Bottles are made of Polypropylrnr and are therefore much lighter than glass. These are autoclavable.

Cap. 5 Lit., 10Lit., 20Lit.

View Detail.
   
ATOMIC MODEL SET
ATOMIC MODEL SET
 

These sets consists of moulded balls of different colours and sizes along with connecting lugs of different sizes. These sets are very helpful in modelling different organic & Inorganic compounds.

Senior Set : This set consists of 150 lugs & 370 balls of prescribed colours and sizes packed in a moulded box having seperate space for every particulars colour & size of ball.

Junior Set : This set consists of 30 connecting lugs & 75 balls of different colours & sizes.

View Detail.
   
ALL TYPE OF I.V. & B.T. DRIP CHAMBERS
ALL TYPE OF I.V. & B.T. DRIP CHAMBERS
 
  • All type of I.V. set & B.A. set drip chambers.
View Detail.
   
Anthropod Collestion
Anthropod Collestion
 
View Detail.
   
ACCESS CONTROL INTERFACE MODULE. MODEL IBL-EBS-21
ACCESS CONTROL INTERFACE MODULE. MODEL IBL-EBS-21
 
This interface provides you a means to understand and program a control required to enter any restricted area. This is called as gaining an access to a restricted area of a building or a department in an industrial setup. These are very common in multistoreged apartment blocks or office complexes. The access can be gained only by using password. This interface module essentially consists of a numeric keypad, with access control keys. On successful entry of the password, an electronic lock opens the simulated door. The access control will be disabled once the door is closed, or when against a specific time interval is elapsed. Since this contains all the necessary hardware interfaces, several of your schemes can be experimented.
View Detail.
   
ACTIVE DIGITAL AUDIO BASS AND TREBLE CONTROL INTERFACE MODULE. MODEL IBL-EBS-23
ACTIVE DIGITAL AUDIO BASS AND TREBLE CONTROL INTERFACE MODULE. MODEL IBL-EBS-23
 
This interface module has digital volume control along with bass and treble control. The necessary interfaces are available on the experimental module including necessary filters. The controller is programmed to accomplish this task.
View Detail.
   
AD 590 TEMPERATURE TRANSDUCER TRAINER. MODEL IBL-AM - 10
AD 590 TEMPERATURE TRANSDUCER TRAINER. MODEL IBL-AM - 10
 

This Trainer makes use of AD-590 Semiconductor Transducer, for measurement. The trainer consists of a heat bar with provision for inserting four AD-590 Transducers. Only one transducer is supplied with the trainer. A built-in heater heats this heat bar. Using this trainer, AD-590 temperature characteristics can be studied.

Specifications:

  • AD-590 Transducer fitted on a heat bar
  • Heat bar Jig with heater.
  • Provision to fix 2 numbers of AD-490 Transducers.
View Detail.
   
ANGULAR POTENTIOMETRIC TRANSDUCER MODULE. MODEL IBL-AM - 16
ANGULAR POTENTIOMETRIC TRANSDUCER MODULE. MODEL IBL-AM - 16
 

Angular potentiometric transducers are used in CNC machine controls, robotic controls, etc. The purpose of this transducer is to measure the angular rotation of a mechanical member subtended from its initial position. This trainer module consists of a graduated potentiometer from 0° to 250°. The output voltage of this is proportional to the angle subtended by this potentiometer. A plot between angular displacement Vs the output voltage is made, to determine the characteristics, of this transducer.

Specifications:

  • Resistance: 1KW
  • Angular rotation: 0° to 250°
  • Output: 0 to 250mV DC, linear
  • Built-in Power supply.
View Detail.
   
AMPLITUDE MODULATION / DE-MODULATION (AM) TRAINER. MODEL IBL-AMD-1
AMPLITUDE MODULATION / DE-MODULATION (AM) TRAINER. MODEL IBL-AMD-1
 
Amplitude modulation is method of transmitting analog signals, usually voice (intelligence) frequency on a high frequency carrier wave. Changing the modulation index varies the amplitude modulation. In this trainer has all the means to achieve this. This trainer consists of both transmitter and receiver. While the carrier wave is internally generated, the voice signal or output of sine generator is usually used as input signals for transmission purposes. This trainer has suitable microphone input, and signal conditioner. At the output it has an audio power amplifier and speaker to receive the demodulated signals. An optional 1 KHz function generator with 1 V PP amplitude, and a dual beam oscilloscope is immensely useful to view the waveforms at different stages of modulation and demodulation.
View Detail.
   
ANTENNA SYSTEM LABORATORY. MODEL IBL-ASL-1
ANTENNA SYSTEM LABORATORY. MODEL IBL-ASL-1
 

Antenna System Laboratory is a very useful acquisition for any modern Electronics & Communications Laboratory. It can be used to practically demonstrate the basic principles of EM Theory.

Introduction:

What is an Antenna?
An antenna is a wire or a group of wires. It converts RF signals, generated by the transmitter, into electromagnetic waves for propagation through space. The receiving antenna receives these EM waves and reconverts them back into the original RF signals for further processing.
The antennas act like interfacing devices between a transmitter and space, and also between space and a receiver.
Thus, both transmitting and receiving antennas have entirely different functions to perform. But they also behave identically (i, e), their behavior is reciprocal.
Any communication system is as good as the antenna it uses. It is completely self-contained for conducting all experiments.
Using ASL-1, the student can understand the basic principles of polarization, directivity, gain and impedance of various types of antennas, in a laboratory environment. In reality, an antenna is a very complex device, with distributed components like inductance, capacitance and resistance spreading all over its length and breath.
They also vary continuously all over its surface and their spread determines the polarization, gain and radiation pattern etc., of an antenna.
Thus, an antenna is an LCR network.
The student can verify them in the laboratory.
Each antenna has its own special features and applications. There is no one best antenna design for all purposes.
Only about 70 types of antenna seem to have been developed so far in the world. Today, 90% of all antennas are vertical, 5% horizontal and 5% other types.

Objectives of Experiments:

Description:
Antenna System Laboratory consists of thirty varieties of antennas fabricated in several shapes and sizes, depending upon the operating frequencies and applications.
a) Eight Stands,
b) One Adjustable TRIPOD,
c) A VHF transmitter (1.5 watts power) with a frequency of about 135-175MHz is supplied for exciting these antennas.
d) One tuned VHF field strength meter. (FSM)
e) One untuned VHF field strength meter. (FSM)
f) VHF Amplifier
g) DIP Meter
h) Voltage Standing Wave Ratio (VSWR) meter.
i) 10meters of coaxial cable, having 50-ohms impedance.
j) A set of ten cables.
k) A detailed instruction manual, for conducting experiments.
Compact Disc (CD):
Compact disc is supplied to understand the details of all thirty antennae. This is simulation software. This is optional requirement. A compact disc (CD), to understand details of all thirty antennas.

Description of the system:
The following antennas are supplied with the ASL-1. Using these antennas, it is possible to study the behavior of each of them for a given transmission and reception medium. The antenna is mounted on a revolving stand. This stand can be manually revolved on a horizontal axis in 3600 with reference to ground plane. It is possible to record and observe the response on a field strength meter (FSM). Using these readings it is possible to draw the POLAR diagram for various angular positions of antenna. Each antenna is a dynamic demonstrator by itself.

Types of antennae supplied are:
1. Vertically Polarized Antenna.
2. Horizontally Polarized Antenna.
3. Circularly Polarized Antenna.
4. Quarter Wave Antenna.
5. Grounded Vertical Antenna.
6. Vertical Half-Wave Dipole Antenna.
7. Horizontal Half-Wave Dipole Antenna.
8. Full Wave Dipole Antenna.
9. Yagi Antenna
A) Folded dipole
B) Folded dipole, with a reflector
C) Folded dipole, with reflector and three directors
10. A loop (frame) Antenna.
11. Quad Loop Antenna.
12. Circular Loop Antenna.
13. AD Cock Antenna.
14. Ferrite Rod Antenna.
15. Helical Antenna.
16. Rhombic Antenna.
17. Endfire Antenna.
18. Broadside Antenna.
19. Collinear Antenna.
20. Log-Periodic Antenna.
21. Top-loaded Antenna.
22. Spiral Antenna.
23. Biconical Antenna.
24. Dipole Antenna, with corner reflector.
25. Turnstile Antenna,
26. Super turnstile Antenna,
27. Batwing Antenna,
28. Discone Antenna,
29. Slot Antenna,
30. Flush Disc Antenna,
31. Cellular Antenna,
32. Pager Antenna,
33. FM Antenna,
34. Horn Antenna,
35. V-Antenna,
36. Active Antenna,
37. Transmission Lines and a probe.

VHF Transmitter: This is a hand-held, variable frequency (135MHz to 175MHz) with 1.5 Watts of VHF output. It can be used both in the field and laboratory environments. It uses a re-chargeable battery. Any "LOW" battery status is indicated, for recharging.
This PLL synthesized digital transmitter has a 4-digit frequency counter, with a 100 KHz resolution.
Its frequency can be varied by both SLOW/FAST controls. It can be modulated externally using a condenser microphone.

Tuned VHF Field Strength meter: This measures RF level of each received signal in mV, (between 1dB to 100dB) in steps of 1dB. This is also battery operated. Convenient for field/laboratory uses.

Tripod: This is used to mount transmitter antenna. This is fixed on a stand, whose height can be varied upto 2 Meters.

Software: This is an optional requirement. Using this simulated software, it is possible to plot radiation patterns on the computer.

What can a student learn? Using this trainer: The following are the objectives. After performing the following listed experiments the student learns
a. The evolution of antenna
b. Understand the current and voltage distributions along its entire length of transmission line and find its characteristic impedance.
c. Measure voltage and current distributions along the length and breadth of antenna.
d. Prepare a perfect earthing system, (an earth mat) or a simulated ground.
e. Understand types of polarization (vertical, horizontal and circular)
f. Understanding the field strength, radiation pattern, power gain and impedance of antennas.
g. Design a half wave dipole for a given frequency.
h. Understand the effect of perfect ground as a reflector.
i. Understand the principle of reciprocity.
j. Understand the principle of directional antennas, for navigational purposes.
k. Understand the effect of reflector and each director in a Yagi Antenna, in terms of gain and radiation pattern.
l. Determine the right type of BALUN.
m. Design at least ten types of antennas and construct them.

List of Experiments:

1) Determination of plane of polarization
2) Measurement of gain
3) Drawing of radiation pattern
4) Calculation of impedance.

View Detail.
   
AM RADIO RECIEVER DEMOSTRATOR. MODEL IBL-RRD-1
AM RADIO RECIEVER DEMOSTRATOR. MODEL IBL-RRD-1
 

The main purpose of a radio receiver is to intercept and decode the radio waves. All radio receivers MUST contain at least these,

1.Antenna system,
2.Tuned circuit,
3.Detector
4.Transducer

When the sound signal is mixed with the carrier frequency then the frequency of the carrier wave remains the same but the amplitude of the carrier changes with the amplitude of the signal. In this case when the amplitude of the carrier waves changes with the amplitude of the sound signals, then the modulation is said to be the Amplitude Modulation or AM.

This type of amplitude modulation is characterized by a lot of disturbance and noise. Consequently, the quality and clarity of the transmitted sound is not quite good. When these AM signal is received on the radio receivers then the quality of the sound reproduced also remains poor.

The main objective of the Super heterodyne receiver is to produce an intermediate frequency (IF) by the process of heterodyne or beating. This can be accomplished when two frequencies are mixed to produce the beat frequency .In superhets, the IF is usually 455 kHz which is selected because the broadcast band begins above that frequency. So if we imagine a situation when the RF amplifier is tuned to receive a 800KHz broadcast signal the local oscillator must be tuned to 1255 kHz which will result in an IF of 455KHz(1255-800 kHz). Since we have to tune the RF amplifier section throughout the entire broadcast band, the frequency of the local oscillator must also vary in a manner that it always maintains a gap of 455kHz. To achieve this condition, the local oscillator and the RF amplifier section are "ganged", i.e., their tuning condensers are connected /ganged mechanically in such a way that when we tune the variable capacitor in the RF section, the variable capacitor in the local oscillator also changes its value it ´tracks´ the frequency to which the ´aerial circuit´ is tuned and remain separated from the tuned frequency by 455kHz up. The intermediate frequency (IF), which is considerably low frequency is being used, because it is a suitable

The demonstrator has several test points for observations. Using these test points, waveforms of incoming signals can be observed using a high frequency oscilloscope.

The test points brought out for observations are:

  • Modulated RF waveform
  • Output of the mixer stage
  • RF amplifier stage
  • Second intermediate frequency stage
  • Detector stage
  • Input of the Power amplifier stage
View Detail.
   
AUTOMATIC TELEPHONE EXCHANGE DEMONSTRATOR. MODEL IBL-TELE - 1
AUTOMATIC TELEPHONE EXCHANGE DEMONSTRATOR. MODEL IBL-TELE - 1
 

The Automatic Telephone Exchange Demonstrator is state of art Microprocessor Technology. It has user friendly commands and is simple to operate. Each function is programmable through the telephone several built-in functions and readily usable. The instrument is housed in an elegant one panel with four wall mountable telephone instruments, with on main and four extensions. These telephone instruments can be used as normal telephone lines through the exchange including intercom facilities. The instruments are normal decade type push-button telephones. All blocks of the instrument are marked and printed on the protective acrylic panel. Various functional blocks EPABX are marked. They are Relay bank for external communication for line calls), relay bank for internal communication (intercom facility), display the current user/users of the exchange. Opto-isolator section, switching section, tone generator/ringer, ringer amplifier, Line coupler/relay/drivers, MICROPROCESSOR, EPROM RAM, buffer section, connection for 4 internal instruments and one external line.

Features:

  • Intercommunication facilities between instruments.
  • Call conference Call forwarding
  • Call transfer Call back
  • Call consult & hold Call pick-up
  • Auto call back Direct dialing
  • Different ring tones Ring polling
  • Music on hold Call restrict local /STD

Specifications:

  • No of lines: one trunk and 4 extensions.
  • Instruments: normal decade dial with 9-11 PPS.
View Detail.
   
AUTOMATIC VOLTAGE STABILIZER DYNAMIC DEMONSTRATOR . MODEL IBL-AVS-1
AUTOMATIC VOLTAGE STABILIZER DYNAMIC DEMONSTRATOR . MODEL IBL-AVS-1
 
This trainer is intended to demonstrate the principles of Voltage stabilizer. The essential parts of controlling BUCK - BOOST, Lower voltage and upper voltage settings etc are demonstrated in this trainer.
View Detail.
   
ARITHMETIC LOGIC UNIT DEMONSTRATOR. MODEL IBL-DM-10
ARITHMETIC LOGIC UNIT DEMONSTRATOR. MODEL IBL-DM-10
 

These arithmetic logic units (ALU)/function generators perform 16 binary arithmetic operations on two 4-bit words. These operations are selected by the four function-select lines (S0, S1, S2, and S3) and include addition, subtraction, decrement and straight transfer. When performing arithmetic manipulations, applying a low-level voltage to the mode control input (M) must enable the internal carries. A full carry look-ahead scheme is available in these devices for fast, simultaneous carry generation by means of two cascade-outputs (P and G) for the four bits in the package. Using this demonstrator it is possible to perform and verify the following functions

  • Two arithmetic operations: Addition and Subtraction of 4-bit binary words.
  • Five logic operations: AND, NAND, OR, NOR, AND exclusive - OR.

In order to accomplish the above tasks, required address selector switches, DATA selector switches, push switches, LED indicators for ADDRESS and DATA are provided in the equipment itself. This trainer comes with necessary power supplies.

View Detail.
   
ANALOG ELECTRONICS LAB. SEMICONDUCTOR DIODE TRAINER MODEL IBL-AN-1
ANALOG ELECTRONICS LAB. SEMICONDUCTOR DIODE TRAINER MODEL IBL-AN-1
 

This trainer is intended to study the Characteristics of Semiconductor Components namely, Diode, Zener Diode, Power Supply Circuit etc. This trainer has built-in power supplies, required components like different types of Diode, Zener Diode, Resistors, Capacitors, Potentiometers, Center Tapped Transformer Output, Variable Power Supplies, Provision for connecting External Meter, etc.

The components provide on the front panel is available across the terminals along with necessary legend and the description. Each component can be patched by inserting single strand hookup wire for establishing contact. The components provided are

Diodes:

  • IN 4007 Silicon diode,
  • BY 127 power diode,
  • OA 79 Germanium diode,
  • 5.1 V Zener diode

Resistors: Each resistor is 1W rating

  • 1 K Ohm
  • 10 K Ohm
  • 47 K Ohm
  • 100 K Ohm

Capacitors : 0.01uF, 0.047uF,0.1uF, and 0.47uF

Potentiometer:

  • 1K/2W Wirewound
  • Provision to connect an external meter
  • 12 - 0 - 12 AC| centertapped transformer output
  • Variable power supply in the range of + 1.2 V DC to +12 V DC and
  • Variable power supply in the range of - 1.2 V DC to -12 V DC
View Detail.
   
ANDERSON BRIDGE. MODEL IBL-AB-1
ANDERSON BRIDGE. MODEL IBL-AB-1
 

Bridge used for the measurement of self - inductance in terms of comparison with a standard capacitance and non-inductive resistance, using the following equation. This bridge has the capability to measure inductance in the range of 350mH - 2H
Lx=C (R3/R4) [R (R4+R2)+R2R4]

In this bridge we are having three sections. A built in oscillator section. A bridge section with six arms. Arm AC consists of non-inductive resistance R3. Arm AD consists of fixed capacitance .Arm CB consists of unknown inductance (Lx). Arm BE consists of non-inductive resistance R2. Arm AE consists of non-inductive resistance R4. Arm DE consists of variable resistance R. The balance of bridge can be observed using a built-in audio amplifier with loudspeaker arrangement. This acts as a null detector.

View Detail.
   
ALTERNATOR
ALTERNATOR
 

This is an AC 3 ? synchronous alternator with, square path, 4 poles, and rotor wound stator excited type. This is screen protected IP22, with drip proof enclosure.

Specifications:

  • Voltage: 415V
  • Amps: 4.2A
  • RPM: 1500
  • KVA-3
  • Rating-CMR
  • Phases-3,Hz-50
  • ENCL-S.P,PF-0.8
  • Extn VOLTS-220
  • Winding-Y
  • Amps-1.4A
View Detail.
   
AC SOLID STATE RELAY. MODEL IBL-PE-4
AC SOLID STATE RELAY. MODEL IBL-PE-4
 

In this trainer two independent solid state relay modules. Are used for connecting AC loads. This relay consists of two TRIACS. The first TRIAC gets a control signal from a digital circuit. There is an opto-isolator between the control circuit and the first TRIAC. Depending on the status of the control signal, the first TRIAC is either activated or not. When activation signal is received by the first TRIAC, it sends gate pulse to second TRIAC. Thus enabling AC load to be activated. The solid state relay used in this trainer comes in the form of a packed module consisting of opto-isolator and TRAIC devices.

This module can at best be used in conjunction with a dedicated hardware or a Microprocessor or a Microcontroller or any other data acquisition system at the time of prototype development or just for experiment. Input signal level: TTL (0 to 5v DC). Output : 230V AC @ 3A.

View Detail.
   
AC PHASE CONTROL USING TRIAC/DIAC. MODEL IBL-PE-9TD
AC PHASE CONTROL USING TRIAC/DIAC. MODEL IBL-PE-9TD
 

AC regulator works on the principle of converting fixed AC voltage to a variable AC voltage operating at the same frequency. This principle is used in speed control of AC drives, pumps, illumination control, temperature control of ovens etc. The devices used for such a control are TRIACS, DIACS and THYRISTORS.

This trainer is intended to provide facility to change the phase angle ? of TRIAC GATE with reference to power line frequency. As a result of this the ON / OFF state of TRIAC is varied, thereby varying RMS value is changed. In this trainer it is possible to measure the phase difference between the input and the output signal. This trainer contains a TRIAC, DIAC necessary firing circuit, and power supply. Load circuit waveforms can be observed through the test points provided. You can connect the load like fan, lamp, pumps, etc. not exceeding max 1A at the load terminal. An isolated 12 AC reference supply is available, for comparing the phase difference at various points on the circuit board, using an external dual beam oscilloscope. In order to connect external loads like fan, lamp, pumps, etc, a separate power socket is available as part of TRIAC circuit. Using this AC loads upto 1 A can be connected. It is very important to note that, HIGH VOLTAGES EXIST on the circuit board, so sufficient and enough care must be taken while measuring the circuit under study.

The entire instrument is housed in an elegant FRP cabinet.

Specifications:

  • Power : 230 V AC @ 50Hz
  • TRIAC Load : AC load not exceeding 1 A.
  • DIAC : 1 No.

An external dual beam oscilloscope is required for measuring and observing the waveforms.
NOTE: Enough care must be taken for isolating AC signals. Qualified staff must be present while conducting this experiment.

View Detail.
   
AC PHASE CONTROL USING THYRISTOR. MODEL IBL-PE-9SCR
AC PHASE CONTROL USING THYRISTOR. MODEL IBL-PE-9SCR
 
This trainer is same as Model PE-9TD, except that instead of TRIAC a two SCRs connected in Anti-parallel mode. This trainer has necessary pulse triggering circuit is also included.
View Detail.
   
Applanation Tonometer
Applanation Tonometer
 

Easy to add on to any HS typr slitlamp/ 2 Japanese Cones / measuring range upto 80mm OF Hg.

Fits onto all haag-Striet type slit - lamps. Provides accurate reading using the Imbert - Fick law. Measuring range from 10mm of Hg to 80mm of Hg, read directly off the graduation scale. 3 measuring optical cones are provided for longer life to the instrument. Calibration system is provided with the instruments

View Detail.
   
Aspherical Lens
Aspherical Lens
 
  • 14D provides high magnification along with an optimized working distance from the cornea
  •  20D diagnostic/laser lenses is perfectly corrected for field curvature, astigmatic aberrations
  •  30D is designed to provide the practitioner a wide field of view with a short working distance
View Detail.
   
Acid Proof Gloves (Red in color)
Acid Proof Gloves (Red in color)
 
View Detail.
   
Acid Proof Gloves (yellow in color)
Acid Proof Gloves (yellow in color)
 
View Detail.
   
Albunometer Tube
Albunometer Tube
 
View Detail.
   
A.C. MODULE
A.C. MODULE
 
It is useful in Front of Air Conditioner to provide a sterile, bacteria free & dust free Air of 0.3 microns in a particular temperature . It works on the Laminar Air Flow Principle .
View Detail.
   
AUTOCLAVE VERTICAL FOR LABORATORY
AUTOCLAVE VERTICAL FOR LABORATORY
 

For sterilization of culture media, glassware, utensils instruments etc. in steam under pressure. Steam lined construction. Outer body is made of thick mild steel sheet finished with cream enamel painted. Inner chamber is made of thick stainless steel. Lid is made of mild steel lined wit stainless steel & provided with a radial locking systems, worked by a handle at the . Gasket is of neoprene rubber, hydraulically tested up to 40 psi. The chamber is absolutely leak proof & can be operated at any selected point in between 5 to 20 pound per sq. inch. It is provide with safety valve pressure gauge, pressure release valve, water level indicator with cord & plug. Fitted with automatic cut off device for element for general safety & also fitted with indfoss piezostat. The lid is made of thick mild steel with stainless steel lined inside duly polished.

Dia x Depth Size

a) 250x450mm (22 Ltrs.)
b) 300x500mm (40 Ltrs.)
c) 350x550mm (50 Ltrs.)
d) 450x600mm (98 Ltrs.)
e) 550x750mm (152 Ltrs.)

View Detail.
   
ABBE REFRACTOMETER
ABBE REFRACTOMETER
 

Abbe Refractometer is a reliable instrument for accurate measurement of Indices of Refraction of transparent liquids, solutions and solids. It can also be used for measurement of dispersion and also for measurement of percentage of Sugar in sugar solutions. From standard tablets the values of refractive indices can be converted in to percentage of sugar.

Permits measurements of refractive indices of liquids, transparent and translucent solutions and solids.

Measurable range extends from 1.300 to 1.700.

Accuracy 0.001 by direct reading and 0.0001 by estimation.

Finely marked glass translucent are scale.

Permits measurement of percentage of sugar.

Permits measurement of dispersion.

Water jacketed prism box; allows measurement of index of refraction at the desired temperature.

Compensator consisting of amici prisms; allows to compensate for dispersion thus making it possible to have a fine critical line.

View Detail.
   
ABBE REFRACTOMETER WITH IMPORTED OPTICS
ABBE REFRACTOMETER WITH IMPORTED OPTICS
 
View Detail.
   
ANTIBIOTIC ZONE READER
ANTIBIOTIC ZONE READER
 
OPTICS TECHNOLOGY offers antibiotic zone reader, most suitable to measure the diameter of the inhibited zone in microbiology, botany, zoology, bacteriology and pathology labs. The instrument is unique in design and measures the diameter of the inhibited zone to 0.1 mm within the range of 0 to 35 mm. Light from a source in the base passes up through the transparent and semitransparent portion of the agar-agar, then to a reflecting mirror supported by an arm above the unit. The mirror reflects the light to a glass prism mounted at the front of the unit and the magnified image of the zone of inhibitions can be clearly seen on the prism. The instrument is supplied complete with all the required accessories like prism, petri dish, etc. The unit is suitable for operation on 230 V, 50 Hz, single phase AC supply.
View Detail.
   
AIR CURTAINS
AIR CURTAINS
 

It is an elegantly designed sleek air curtain with a specially designed line flow fan capable of producing a uniform and powerful curtain of air, at a very low noise leave.

TECHNICAL DATA

Door OpeningVel. FPM at
Pressure at
Motor
Width HeightNozzleNozzleH.P. RPM
36"7"2100 500 0.25 1440
42"7"2250 600 0.25 1440
48"7"2250 600 0.33 1440
60"7"2300800 0.50 1440
72"7"2500 1200 0.50 1440

IN AIR CONDITIONED INTERIORS

  • Cuts down Air Conditioning costs incredibly.
  • Shut out insects totally.
  • Shuts out Dust & Fumes totally.
  • Allows free movement of people and material.
  • Prevents loss of cooling/heating effects of air.

USEFUL FOR :

  • Air Conditioned Show Rooms
  • Restaurants and Hotels
  • Receiving Areas
  • Computer Rooms
  • Cold Storage
  • Hospitals
  • Nursing Homes
  • Operation Theatres etc..
View Detail.
   
Automatic Sterilizer
Automatic Sterilizer
 



ModelNominal Rating mg/hr ozoneRoom Volume (In Ft3)Air Flow (4-5 hrs.) CFMPower (W)Dimensions HXBXW (In mm)Weight (Kgs)
TI - 0.25 250 1500 105 40 180 x 150 x 260 2.0
TI - 0.50 500 3000 105 80 280 x 240 x 350 3.0
TI - 0.75750 4500 310 100 240 x 150 x 350 4.5
View Detail.
   
Aspheric Lens
Aspheric Lens
 
We at Chona surgical specialise in offering wide array of aspheric lens whose surfaces have a profile that is neither a portion of a sphere nor of a circular cylinder. In photography, a lens assembly that includes an aspheric element is often called an aspherical lens. These products are available in there configurations: 20 D, 78 D & 90 D
View Detail.
   
Artifical Eye
Artifical Eye
 
Optimizing on the in-depth industry experience and skilled oculists, we offer a wide range of artificial eyes that is used to restore the natural appearance of the eye and surrounding tissues. We manufacture these artificial eyes from superior quality plastic (acrylic) or glass. Our highly skilled oculists (eye makers) are also adept at hand-crafting these eyes so as to the natural eye.
View Detail.
   
Aids Virus
Aids Virus
 

AIDS VIRUS HIV virus model is enlarged millions of times, shows the outer lipid membrane with protein structures and the internal nucleus which contains the viral hereditary matter [RNA]. The nucleus is removable and condoms can be put underneath to provide a message regarding measures to be taken for protecting against HIV infections.Supplied without condoms, on stand,with key card.

View Detail.
   
Amoeba Proteus
Amoeba Proteus
 

A true three dimensional model showing detailed structure, mounted on base, with key card. Overall dimensions 345 x 195 x 210 mm. approx.

View Detail.
   
Amoeba Proteus 2 Parts
Amoeba Proteus 2 Parts
 

Enlarged approx.1000 times. A small pseudopodium which can be opened up showing the structure as under electron microscope magnification. Separates into 2 parts, on base with key card. Size 480 x 310 x 80 mm.approx.

View Detail.
   
Anatomy Of Starfish
Anatomy Of Starfish
 

Showing the general structure, internal viscera, water vascular system and arm in T.S. showing details of tube feet, mounted on board, with key card. Overall dimensions 500 x 450 x 75 mm.approx.

View Detail.
   
Animal Cell
Animal Cell
 

Typical,a three dimensional model with one side dissected to show complete internal structures,mounted on base,with key card. Overall dimensions 220 x 130 x 430 mm.approx.

View Detail.
   
Animal Cell Division Mitosis
Animal Cell Division Mitosis
 

A set of 9 models, showing the process of mitotic cell division. The chromosomes are painted for easy identification.Models are approx. 150 x 120 mm.

View Detail.
   
Animal Cell Division, Meiosis
Animal Cell Division, Meiosis
 

A set of 12 models, showing detailed stages in meiotic cell division, realistically coloured to bring out the detailed structures as seen under a microscope. A very useful and instructive model, mounted on board, with key card. Overall dimensions 510 x 450 x 50 mm.approx

View Detail.
   
Air Rotor Control
Air Rotor Control
 
One three way Syringe and provision for Air Motor and Air Rotor hand piece
View Detail.
   
Air Rotor Control Box
Air Rotor Control Box
 
One three way Syringe and provision for air rotor hand piece
View Detail.
   
 
 
Biology Lab Instruments | Physics Lab Instruments | Chemistry Lab Instruments | Laboratory Equipment | Educational Equipment | Hospital and Medical Equipment | Rehabilitation Aids Manufacturers | Oil & Petroleum Testing Instruments
 

Home | About us | Request Call Back | Enquiry | Request Catalogue | Report A Bug | Request Sample | Products | Downloads
Contact us | Exhibition | Full Products Range | Tender Enquiry

Copyright © Naugra Export 2009. All right reserved.